Water Distribution Network

Monitor and manage water distribution across Sydney zones

Sydney CBD Distribution Zone

45,000 customers • 2850 L/min flow rate

OPTIMAL
Efficiency: A+
Primary Booster Pump P-001

Sydney CBD StationCentrifugal Pump

8% Failure Risk (30 days)
Operational

Flow Rate

2850 L/min

Pressure

85 kPa

Power Draw

247 kW

Runtime

18760 hrs

Vibration Level4.2 mm/s
Temperature58°C
Bearing Condition92%

24-Hour Vibration Analysis

00:0006:0012:0018:0024:00
Maintenance Recommendations
  • Schedule bearing lubrication within 2 weeks
  • Monitor vibration levels daily
  • Check alignment during next maintenance window
Secondary Pump P-002

North Shore DistributionVariable Speed Pump

24% Failure Risk (30 days)
Operational

Flow Rate

2340 L/min

Pressure

78 kPa

Power Draw

189 kW

Runtime

15420 hrs

Vibration Level6.8 mm/s
Temperature72°C
Bearing Condition78%

24-Hour Vibration Analysis

00:0006:0012:0018:0024:00
Maintenance Recommendations
  • Replace bearings within 30 days
  • Inspect impeller for wear
  • Consider pump overhaul
  • Increase monitoring frequency to twice daily
Backup Pump P-003

Eastern Suburbs HubHigh Pressure Pump

3% Failure Risk (30 days)
Standby

Flow Rate

0 L/min

Pressure

0 kPa

Power Draw

0 kW

Runtime

8940 hrs

Vibration Level2.1 mm/s
Temperature35°C
Bearing Condition96%

24-Hour Vibration Analysis

00:0006:0012:0018:0024:00
Maintenance Recommendations
  • Excellent condition - continue routine maintenance
  • Test run monthly to ensure readiness
  • Standard 6-month service interval
Distribution Pump P-004

Inner West NetworkMulti-Stage Pump

42% Failure Risk (30 days)
Operational

Flow Rate

2180 L/min

Pressure

76 kPa

Power Draw

198 kW

Runtime

22150 hrs

Vibration Level9.2 mm/s
Temperature81°C
Bearing Condition65%

24-Hour Vibration Analysis

00:0006:0012:0018:0024:00
Maintenance Recommendations
  • URGENT: Schedule immediate maintenance
  • Replace bearings and seals
  • Check motor alignment
  • Consider temporary pump replacement
  • Increase monitoring to hourly intervals
Transfer Pump P-005

Western Sydney MainAxial Flow Pump

16% Failure Risk (30 days)
Operational

Flow Rate

3890 L/min

Pressure

74 kPa

Power Draw

289 kW

Runtime

19680 hrs

Vibration Level5.4 mm/s
Temperature64°C
Bearing Condition84%

24-Hour Vibration Analysis

00:0006:0012:0018:0024:00
Maintenance Recommendations
  • Schedule bearing inspection within 4 weeks
  • Monitor temperature trends